IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & R190-225NE
ingersollrandproducts.com
61
EN
8.0 GENERAL INFORMATION
KEY
1ATS
Switch, high air end discharge temperature
1DPS Switch, fouled oil filter
1VAC Switch, fouled air filter
1ATT
Sensor, airend inlet
2ATT
Sensor, airend discharge temperature
2CTT
Sensor, injected coolent temperature
3APT
Transducer, sump pressure, wet side
3SV
Valve, blowdown solenoid
4APT
Transducer, package air discharge pressure
4ATT
Sensor, package air discharge temperature
4CTT
Sensor, oil cooler out temperature
4SV
Valve, water stop solenoid (W.C. only)
6APT
Transducer, sump air pressure, dry side
9APT
Transmitter, remote air pressure (optional)
9SV
Valve, condensate drain
11SV
Valve, anti-condensation solenoid
AT
Auto transformer (if fitted)
AW1
Auxiliary warning 1
AW2
Auxiliary warning 2
BP
Backplate
C
Capacitor
CAB
Cabinet
CDE
Condensate drain error
CDV
Condensate drain valve (if fitted)
CFO
Common fault output
CK
Choke
EXC
External communications
DR
Drive
DVF
Fan, drive box ventilation
EB
Earth bar
ES
Switch, emergency stop
FD
Drive, blower (A.C. only)
FM
Motor, blower
GND
Ground
HTR1 Heater, spacer 25 watts
HTR2 Heater, spacer 25 watts
K1
Relay, run
K2
Relay, fault
KM1
Contactor, main motor
KM4
Contactor, fan motor (W.C. only)
KM5
Contactor, drive ventilation fan
MCB1 Breaker, miniature circuit, transformer
MCB2 Breaker, miniature circuit, DVF
MCB3 Breaker, miniature circuit, VFD supply
MCB4 Breaker, miniature circuit, VFD supply
MCB5 Breaker, miniature circuit, PSU
MCB9 Breaker, miniature circuit, heaters
MF
Mains filter (if fitted)
MM
Motor, main
MMS
Breaker, fan motor
OPT
Optional
OV
Zero voltage
PE
Protected earth
PORO Power outage restart option (optional)
PSU
Power supply unit
RFI
Filter, radio frequency interference
RSP
Remote stop
RST
Remote start
SGNE Controller, intellisys
SL
Serial link
SS1-3 Relay, solid state
ST
Service tool
T1
Transformer, control
TH
Thermostat
TRR
True running
WR
General warning
Colors
BLK
Black
BLU
Blue
BRO
Brown
GRE
Green
PIN
Pink
RED
Red
SCR
Screened
VIO
Violet
WHI
White
YEL
Yellow
Wires
Numbers
Function
Wire color
1-99
100-199
200-299
300-399
Power
AC Control
DC Control
Auxiliary
Black
Red
Blue
Orange
Notes:
1. Factory supplied as shown by connection to output of
control transformer t1. Wire number 100 & 121.
2. Alternatively the supply may be taken from an
Independent source: in that case, factory supplied
connection must be disconnected.
3. Ensure parallel connection of heaters.
Notes:
1. Connections for use on 200/230v systems. The supply
is independent of the main compressor. The customer
must provide an isolator / disconnect switch adjacent to
the machine for this supply. In that case, factory supplied
connection must be disconnected.
2. Ensure series connection of heaters.
111213.14.59
Summary of Contents for IRN100-200H-2S
Page 101: ...111213 14 59 ...
Page 102: ...ingersollrandproducts com 2013 Ingersoll Rand 111213 14 59 ...