11.0 FAULT FINDING
SYMPTOM
FAULT
REMEDY
Pressure produced by
compressor is too high
compressor is too high due to
speed not reducing as demand
reduces
Intellisys set incorrectly
Check and modify settings
Pressure transducer may be
faulty, incorrectly calibrated or
not receiving pressure signal
Recalibrate or replace
Drive settings fault
Contact your local IR representative
Compressor discharge air too
hot
High ambient temperature
Review installation and system parameters
Insufficient cooling air
Check ducting and cooling air path, check
direction of blower rotation
Blocked aftercooler matrix
Clean or replace
Compressor package produces
excessive noise
Panels or doors are not closed
properly
Rectify fault
Air leaks from internal pipework /
components
Overhaul or replace
Blower or blower motor bearings
worn
Overhaul or replace
Loose debris impacting on
blower during rotation
Remove and rectify any damage
Blowdown valve stuck open
Overhaul or replace
Pressure relief valve not seating
correctly
Overhaul or replace
Vibration due to motor, airend or
blower imbalance
Overhaul or replace
Airend requires overhaul
Contact your local IR representative
Discharge air is contaminated
with coolant
Scavenge pipe is blocked, broken
or o-ring is not sealing
Clean or replace
Separator element is punctured,
or incorrect, or requires changing,
or not sealing correctly
Replace
Incorrect coolant has been added Drain system, check for damage. Clean, refill
with correct coolant
System has been overfilled with
coolant
Check for damage, drain excess