EonStor CS Installation Guide
page 38 / 165
Installation Guide
Message
Logical drive member drive failed
1st Line Message
Old Message
ID:%.1x Logical Drive ALERT: CHL:%.1d ID:%.1d Drive Failure
Cause
Specific member drive of logical drive failed.
1. User removed the drive.
2. Drive failed.
3. Backplane connection issue.
Action
1. Insert the drive back and rebuild the Logical Drive if needed.
2. Replace the failed drive and engage the logical drive
rebuilding operation manually or automatically to recover logical
drive.
3. If it is still failed after replacing with a new drive, replace the
backplane.
Summary of Contents for EonStor GS 1000 Gen2
Page 19: ...EonStor CS Installation Guide page 19 165 Installation Guide Troubleshooting Flow Chart...
Page 33: ...EonStor CS Installation Guide page 33 165 Installation Guide...
Page 44: ...EonStor CS Installation Guide page 44 165 Installation Guide...
Page 52: ...EonStor CS Installation Guide page 52 165 Installation Guide...
Page 53: ...EonStor CS Installation Guide page 53 165 Installation Guide...
Page 63: ...EonStor CS Installation Guide page 63 165 Installation Guide...
Page 64: ...EonStor CS Installation Guide page 64 165 Installation Guide...
Page 75: ...EonStor CS Installation Guide page 75 165 Installation Guide...
Page 106: ...EonStor CS Installation Guide page 106 165 Installation Guide...
Page 118: ...EonStor CS Installation Guide page 118 165 Installation Guide...
Page 127: ...EonStor CS Installation Guide page 127 165 Installation Guide...
Page 137: ...EonStor CS Installation Guide page 137 165 Installation Guide...
Page 140: ...EonStor CS Installation Guide page 140 165 Installation Guide...
Page 156: ...EonStor CS Installation Guide page 156 165 Installation Guide...
Page 159: ...EonStor CS Installation Guide page 159 165 Installation Guide...