1
6
C
and
D.
HOOD
420
Min.
min.
650
mm. with hood
min.
700
mm. without hood
mm.
600
Min.
mm.
420
Min.
mm.
HOOD
900
Min.
mm.
420
Min.
min.
650
mm. with hood
min.
700
mm. without hood
mm.
420
Min.
mm.
Fig.
C
Fig.
D
Connecting the
G
as
Th
e
appliance
s
h
ould
be
connected
to
t
h
e
mains
or
to
a
gas
c
y
linder
in
compliance
wit
h
current
N
ational
R
egula
-
tions.
Before
ma
k
ing
t
h
e
connection
,
c
h
ec
k
t
h
at
t
h
e
coo
k
er
is
regulated
for
t
h
e
gas
suppl
y
y
ou
are
using.
If
not
,
follow
t
h
e
instructions
indicated
in
t
h
e
paragrap
h
“
Adapting
to
different
t
y
pes
of
gas.
"
O
n
some
models
t
h
e
gas
suppl
y
can
be
connected
on
t
h
e
left
or
on
t
h
e
rig
h
t
,
as
neces
-
sar
y
;
to
c
h
ange
t
h
e
connection
,
re
v
erse
t
h
e
position
of
t
h
e
h
ose
h
older
wit
h
t
h
at
of
t
h
e
cap
and
replace
t
h
e
gas
-
k
et
(
supplied
wit
h
t
h
e
appliance
)
.
Wh
en
using
li
q
uid
gas
from
a
c
y
linder
,
install
a
pressure
regulator
w
h
ic
h
com
-
plies
wit
h
t
h
e
current
N
ational
R
egulations.
Important:
C
h
ec
k
t
h
at
t
h
e
suppl
y
pressure
complies
wit
h
t
h
e
v
alues
indicated
in
table
1
“
Burner
and
N
o
zz
le
C
h
ar
-
acteristics
”
since
t
h
is
will
ensure
safe
operation
,
correct
consumption
and
ensure
a
longer
life
for
y
our
appliance.
Connection with a Hose
M
a
k
e
t
h
e
connection
using
a
gas
h
ose
t
h
at
complies
wit
h
re
q
uirements
set
fort
h
b
y
t
h
e
current
N
ational
R
egulations.
Th
e
inner
diameters
of
t
h
e
pipe
are
as
follows
:
-
8
mm
for
li
q
uid
gas
;
-
1
3
mm
for
met
h
ane
gas.
Wh
en
installing
t
h
e
h
ose
,
remember
to
ta
k
e
t
h
e
following
precautions
:
•
N
o
part
of
t
h
e
h
ose
s
h
ould
touc
h
parts
w
h
ose
tem
-
perature
e
x
ceeds
50°
C
;
•
Th
e
lengt
h
of
t
h
e
h
ose
s
h
ould
be
less
t
h
an
1500
mm
;
•
Th
e
h
ose
s
h
ould
not
be
sub
j
ect
to
twisting
or
pulling
,
and
s
h
ould
not
h
a
v
e
bends
or
k
in
k
s
;
•
Th
e
h
ose
s
h
ould
not
touc
h
ob
j
ects
wit
h
s
h
arp
edges
,
mo
v
ing
parts
,
and
it
s
h
ould
not
be
crus
h
ed
;
•
Th
e
full
lengt
h
of
t
h
e
h
ose
s
h
ould
be
eas
y
to
inspect
in
order
to
c
h
ec
k
its
condition.
C
h
ec
k
t
h
at
t
h
e
h
ose
fits
firml
y
into
place
at
t
h
e
two
ends
and
fi
x
it
wit
h
clamps
compl
y
ing
wit
h
current
N
ational
R
egulations.
If
an
y
of
t
h
e
abo
v
e
recommendations
can
not
be
followed
,
fle
x
ible
metal
pipes
s
h
ould
be
used.
If
t
h
e
coo
k
er
is
installed
according
to
t
h
e
conditions
of
Class
2
,
subdi
v
ision
1
,
onl
y
a
fle
x
ible
metal
pipe
w
h
ic
h
is
in
com
-
pliance
wit
h
current
safet
y
standards
s
h
ould
be
used
to
ma
k
e
t
h
e
connection
to
t
h
e
gas
mains.
Connecting a Fle
x
ible, Jointless, Stainless Steel
Pipe to a Threaded Attachment
R
emo
v
e
t
h
e
h
ose
h
older
fitted
on
t
h
e
appliance.
Th
e
gas
suppl
y
pipe
fitting
is
a
t
h
readed
1
/
2
gas
c
y
lindrical
male
attac
h
ment.
O
nl
y
use
pipes
and
gas
k
ets
compl
y
ing
wit
h
current
standards.
Th
e
full
lengt
h
of
t
h
e
pipe
must
not
e
x-
ceed
2000
mm.
O
nce
t
h
e
connection
h
as
been
made
,
ensure
t
h
at
t
h
e
fle
x
ible
metal
pipe
does
not
touc
h
an
y
mo
v
ing
parts
and
is
not
crus
h
ed.
Chec
k
ing that the Connection is Tight
Important:
Wh
en
installation
h
as
been
completed
,
c
h
ec
k
t
h
e
pipe
fittings
for
lea
k
s
using
a
soap
y
solution.
N
e
v
er
use
a
flame.
O
nce
t
h
e
connection
h
as
been
made
,
ensure
t
h
at
t
h
e
fle
x
ible
metal
pipe
does
not
touc
h
an
y
mo
v
ing
parts
and
is
not
crus
h
ed.
Connecting the Power Supply Cord to the
M
ains
Install
a
normalised
plug
corresponding
to
t
h
e
load
indi
-
cated
on
t
h
e
data
plate.
Wh
en
connecting
t
h
e
cable
di
-
rectl
y
to
t
h
e
mains
,
install
an
omnipolar
circuit
-
brea
k
er
wit
h
a
minimum
contact
opening
of
3
mm
between
t
h
e
appli
-
ance
and
t
h
e
mains.
Th
e
omnipolar
circuit
brea
k
er
s
h
ould
be
si
z
ed
according
to
t
h
e
load
and
s
h
ould
compl
y
wit
h
current
regulations
(
t
h
e
eart
h
wire
s
h
ould
not
be
inter
-
rupted
b
y
t
h
e
circuit
brea
k
er
)
.
Th
e
suppl
y
cable
s
h
ould
be
positioned
so
t
h
at
it
does
not
reac
h
a
temperature
of
more
t
h
an
50°
C
wit
h
respect
to
t
h
e
room
temperature
,
along
its
lengt
h
.
Before
ma
k
ing
t
h
e
connection
,
c
h
ec
k
t
h
at
:
•
Th
e
limiter
v
al
v
e
and
t
h
e
h
ome
s
y
stem
can
support
t
h
e
appliance
load
(
see
data
plate
)
;
•
Th
e
mains
are
properl
y
eart
h
ed
in
compliance
wit
h
cur
-
rent
standards
and
regulations
;
•
Th
ere
is
eas
y
access
to
t
h
e
soc
k
et
and
omnipolar
cir
-
cuit
brea
k
er
,
once
t
h
e
h
ob
h
as
been
installed.
NB:
N
e
v
er
use
reducers
,
adaptors
or
s
h
unts
since
t
h
e
y
can
cause
h
eating
or
burning.
Converting the Hob for Different Types of
G
as
In
order
to
con
v
ert
t
h
e
coo
k
er
to
a
different
t
y
pe
of
gas
wit
h
respect
to
t
h
e
gas
for
w
h
ic
h
it
was
manufactured
(
in
-
dicated
on
t
h
e
label
attac
h
ed
to
t
h
e
lid
),
follow
t
h
ese
steps
:
a
)
R
eplace
t
h
e
h
ose
h
older
mounted
on
t
h
e
appliance
wit
h
t
h
at
supplied
in
t
h
e
bag
of
“
coo
k
er
accessories.
”
Important:
Th
e
h
ose
h
older
for
li
q
uid
gas
is
mar
k
ed
8
,
t
h
e
h
ose
h
older
for
met
h
ane
gas
is
mar
k
ed
1
3
.
Alwa
y
s
use
a
new
sealing
gas
k
et.
b
)
R
eplace
t
h
e
burner
no
zz
les
on
t
h
e
h
ob
:
•
R
emo
v
e
t
h
e
grids
and
slide
t
h
e
burners
from
t
h
eir
h
ousings
;
•
U
nscrew
t
h
e
no
zz
les
using
a
7
mm
soc
k
et
spanner
,
and
replace
t
h
em
wit
h
no
zz
les
for
t
h
e
new
t
y
pe
of
gas
(
see
table
1
“
Burner
and
N
o
zz
le
C
h
aracteristics
”)
.
•
R
eplace
all
t
h
e
components
b
y
repeating
t
h
e
steps
in
re
v
erse
order.
Summary of Contents for K6T52S/I
Page 12: ...12 Consigli pratici per la cottura x 0 w 0 0 1 0 0 2 4 x 4 5 5 5 5 5 5 5 5 5 0 x x x ...
Page 46: ...46 ...
Page 47: ...47 ...