Page | 127
If communication is established, the target indicator will show the mode of the controller
Target: yy(R)
as shown in the status section above in this chapter, section I³ Config Status Bar.
Local ID and Target ID
Match
If the controller is not communicating, you may need to set the Target ID of the controller in
i
³
Config or change the controllers ID on the unit itself. The
Target ID
allows directing communications
to a unit when multiple units are connected via an iCAN network. Units without ICAN network ports
respond to any network ID and do not require the ID to be configured.
The main method for communicating between
i
³ Config and an
i
³C Lite is RS-232 serial. The controller
can communicate with
i
³ Config using USB to serial adapters, CAN (iCAN) or modems. For
communications other than RS-232 serial please refer to the manual that ships with the adapter
hardware being used for programming.
NOTE:
The following fields need to be filled for communication configuration if
i
³ Config Connection
Wizard was not used. Table 15.1 explains the information needed in each field.
5.
Target Name
6.
Connection Medium
7.
Connected Device
8.
Connection Settings
When connected directly to the controller to which
i
³
configurator communications are required, the
Local ID
and the Target ID should match.
Summary of Contents for i3C Lite
Page 1: ......
Page 8: ...Page 8 ...
Page 65: ...Page 65 Figure 9 3 Screen Calibration ...
Page 78: ...Page 78 Figure 11 2 Relay and Digital Output ...
Page 82: ...Page 82 Figure 11 5 Digital Input ...
Page 86: ...Page 86 11 9 RTD Wiring on J3 Connector ...
Page 110: ...Page 110 Figure 13 8 Alarm Configuration in i Config ...
Page 167: ...Page 167 ...