49
STV2I ed 11/09
VICTRIX 2 I Export
Technical Documentation
Technical Documentation
- Fume temperature values refer to an air inlet temperature of
15°C.
- The data relevant to domestic hot water performance refer to a
dynamic inlet pressure of 2 bar and an inlet temperature of 15°C;
the values are measured directly at the boiler outlet considering that
to obtain the data declared mixing with cold water is necessary.
- The maximum sound level emitted during boiler operation is <
55dBA. The sound level value is referred to semianechoic chamber
tests with boiler operating at max. heat output, with extension of
fume exhaust system according to product standards.
VICTRIX X 24 2 I technical data.
Domestic hot water nominal heat input (optional)
kW (kcal/h)
26.7 (22933)
Central heating nominal heat input
kW (kcal/h)
24.1 (20747)
Minimum heat input
kW (kcal/h)
3.2 (2719)
Domestic hot water nominal heat output (useful) (optional)
kW (kcal/h)
26.0 (22360)
Central heating nominal heat output (useful)
kW (kcal/h)
23.6 (20296)
Minimum heat output (useful)
kW (kcal/h)
3.0 (2580)
Efficiency 80/60 Nom./Min.
%
97.8 / 94.9
Efficiency 50/30 Nom./Min.
%
106.7 / 103.0
Efficiency 40/30 Nom./Min.
%
108.1 / 107.1
Heat loss at casing with burner On/Off (80-60°C)
%
0.41 / 0.50
Heat loss at flue with burner On/Off (80-60°C)
%
0.02 / 2.00
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature Pos 1
°C
25 - 85
Adjustable central heating temperature Pos 2
°C
25 - 50
System expansion vessel total volume
l
5.7
Heating expansion tank pre-charge
bar
1.0
Water content in generator
l
3.4
Total head available with 1000/h flow rate
kPa (m H
2
O)
18.63 (1.90)
*Specific capacity “D” UB Immergas 80 l (∆T 30°C) according to EN 625
l/min
20.5
*Specific capacity “D” UB Immergas 105 l (∆T 30°C) according to EN 625
l/min
24.8
*Specific capacity “D” UB Immergas 120 l (∆T 30°C) according to EN 625
l/min
27.1
*Specific capacity “D” UB Immergas 200 l (∆T 30°C) according to EN 625
l/min
35.7
Drawing capacity in continuous duty with UB Immergas (∆T 30°C)
l/min
12.4
Weight of full boiler
kg
41.6
Weight of empty boiler
kg
38.2
Electric connection
V/Hz
230/50
Power input
A
0.61
Installed electric power
W
135
Pump consumption
W
83.5
Fan consumption
W
10
Equipment electrical system protection
-
IPX4D
Flue gas max. temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
39.0
Weighted CO
mg/kWh
17.2
Type of appliance
C13 / C23 / C33 / C43 / C53 / C83 / B23p
/ B33p
Category
II2H3B/P
Summary of Contents for VICTRIX 26 2 I