1
STV2I ed 11/09
VICTRIX 2 I Export
Technical Documentation
Technical Documentation
VICTRIX 26 2 I
Wall-hung, sealed, condensing boiler for cen-
tral heating and the instant production of
domestic hot water.
VICTRIX 26 2 I
VICTRIX 26 2 I is a wall-hung sealed instant boiler (type C)
with useful heat output of 23.6 kW (20,296 kcal/h) in central
heating mode and 26 kW (22,360 kcal/h) in domestic hot water
mode which, thanks to condensing technology, distinguishes
itself due to its high efficiency and large field of modulation
(from 10 % to 100 % of the nominal heat output)
.
The boiler has a total premix combustion system that gua-
rantees particularly reduced pollutant emissions and allows
functioning with natural gas or LPG.
The VICTRIX 26 2 I range are type-approved for installation
outside the building in a partially protected place.
N.B.:
A partially protected location is one in which the appliance
is not exposed to the direct action of the weather (rain, snow,
hail, etc..).
Adjustment and control of the appliance are entrusted to a
P.C.B. with micro processor with continuous flame modulation
by means of 2 sensors (
DHW and CH
), which using a back-
lit display shows the boiler functioning status (
temperatures,
safety devices, etc.
)and allows connection (
optional
) to the
Comando Amico Remoto remote control. the external probe,
the zone control unit and the DIM
(multi-system distribution
manifold).
The boiler uses a new condensation module;
its inside part is
realised in a stainless steel coil shape and makes up the sealed
combustion chamber and the combustion chamber, while the
external part (
casing
) is made in composite material and also
encloses the flue hood.
As well as the new condensation model (
water gas heat
General features.
exchanger) the hydraulic circuit is also made up from the
hydraulic unit in composite material.
Along with the pump, this unit houses the electric 3-way valve
and the hydraulic circuit control devices
(3 bar safety valve,
automatic system by-pass, etc...)
.
The
new electric 3-way valve group
allows, according to ne-
cessity, the circulation of the boiler water in the central heating
system or in a stainless steel plate heat exchanger for the instant
production of domestic hot water.
A domestic hot water flow switch allows the activation of the
boiler in the case of the request for domestic hot water, while
a system flow switch controlling the correct circulation of
water in the boiler allows the activation of the boiler both for
a domestic hot water and central heating request.
The boiler has
anti-freeze safety device as per standard
that
protects it to a minimum temperature of
-5°C
(optional to
-15°C).
The VICTRIX 26 2 I boiler must be installed using the intake/
exhaust kits or the ducting systems (
Ø 60 mm rigid, Ø 80 mm
rigid and Ø 80 mm flexible
) realised in plastic and designed
expressly for Immergas condensing boilers.
Summary of Contents for VICTRIX 26 2 I
Page 2: ......