51
STV2I ed 11/09
VICTRIX 2 I Export
Technical Documentation
Technical Documentation
VICTRIX X 12 2 I variable heat output.
VICTRIX X 12 2 I combustion parameters.
METHANE (G20)
BUTANE (G30)
PROPANE (G31)
HEAT
OUTPUT
HEAT
OUTPUT
BURNER
GAS FLOW RATE
PRESS. NOZZLES
PRESSURE
BURNER
GAS FLOW RATE
PRESS. NOZZLES
PRESSURE
BURNER
GAS FLOW RATE
PRESS. NOZZLES
PRESSURE
(kW)
(kcal/h)
(m
3
/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
12.0
10320
1.30
5.69
58.0
0.97
5.33
54.3
0.95
6.59
67.2
11.0
9460
1.19
4.75
48.4
0.89
4.45
45.4
0.87
5.50
56.0
10.0
8600
1.08
3.91
39.8
0.81
3.67
37.5
0.79
4.52
46.1
9.8
8456
1.06
3.78
38.5
0.79
3.55
36.2
0.78
4.37
44.6
8.0
6880
0.87
2.50
25.5
0.65
2.36
24.1
0.64
2.90
29.5
7.0
6020
0.76
1.92
19.6
0.57
1.82
18.6
0.56
2.23
22.7
6.0
5160
0.66
1.43
14.5
0.49
1.36
13.8
0.48
1.65
16.8
5.0
4300
0.55
1.00
10.2
0.41
0.96
9.8
0.40
1.16
11.9
4.0
3440
0.44
0.66
6.7
0.33
0.63
6.4
0.33
0.76
7.8
3.0
2580
0.34
0.39
4.0
0.25
0.37
3.8
0.25
0.45
4.6
2.0
1720
0.23
0.20
2.0
0.17
0.19
1.9
0.17
0.23
2.4
1.9
1634
0.22
0.19
1.9
0.16
0.18
1.8
0.16
0.22
2.2
G20
G30
G31
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Gas nozzle diameter
mm
3.70
2.80
2.80
Flue flow rate at max heat output
kg/h
19
17
20
Flue flow rate at min heat output
kg/h
3
3
3
CO
2
at Q. Nom./Min.
%
9.50 / 8.85
12.50 / 11.60
10.60 / 10.20
CO at 0% of O
2
at Q. Nom./Min.
ppm
110 / 4
440 / 4
115 / 1
NO
X
a 0% of O
2
at Q. Nom./Min.
mg/kWh
48 / 13
185 / 19
83 / 28
Flue temperature at nominal output
°C
56
62
56
Flue temperature at minimum output
°C
58
64
59