48
STV2I ed 11/09
VICTRIX 2 I Export
Technical Documentation
Technical Documentation
VICTRIX X 12 2 I technical data.
- Flue temperature values refer to an air inlet temperature of 15°C
and flow temperature of 50°C.The data relevant to domestic hot
water performance refer to a dynamic inlet pressure of 2 bar and an
inlet temperature of 15°C; the values are measured directly at the
boiler outlet considering that to obtain the data declared mixing
with cold water is necessary.
- The maximum sound level emitted during boiler operation is <
55dBA. The sound level value is referred to semianechoic chamber
tests with boiler operating at max. heat output, with extension of
fume exhaust system according to product standards.
- * Specific capacity “D”: domestic hot water flow rate corresponding
to an average increase of 30K, which the boiler can supply in two
successive withdrawals.
Nominal heat input
kW (kcal/h)
12.3 (10563)
Minimum heat input
kW (kcal/h)
2.0 (1753)
Nominal heat output (useful)
kW (kcal/h)
12.0 (10320)
Minimum heat output (useful)
kW (kcal/h)
1.9 (1634)
Efficiency 80/60 Nom./Min.
%
97.7 / 93.2
Efficiency 50/30 Nom./Min.
%
106.9 / 102.4
Efficiency 40/30 Nom./Min.
%
107.0 / 106.8
Heat loss at casing with burner On/Off (80-60°C)
%
0.89 / 0.30
Heat loss at flue with burner On/Off (80-60°C)
%
0.02 / 2.00
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature Pos 1
°C
25 - 85
Adjustable central heating temperature Pos 2
°C
25 - 50
System expansion vessel total volume
l
5,7
Heating expansion tank pre-charge
bar
1.0
Water content in generator
l
3.0
Total head available with 1000/h flow rate
kPa (m H
2
O)
8.24 (0.84)
*Specific capacity “D” UB Immergas 80 l (∆T 30°C) according to EN 625
l/min
17.2
*Specific capacity “D” UB Immergas 105 l (∆T 30°C) according to EN 625
l/min
21.0
*Specific capacity “D” UB Immergas 120 l (∆T 30°C) according to EN 625
l/min
21.1
*Specific capacity “D” UB Immergas 200 l (∆T 30°C) according to EN 625
l/min
22.1
Drawing capacity in continuous duty with UB Immergas (∆T 30°C)
l/min
6.3
Weight of full boiler
kg
39.5
Weight of empty boiler
kg
36.5
Electric connection
V/Hz
230/50
Power input
A
0.55
Installed electric power
W
120
Pump consumption
W
80.7
Fan consumption
W
9.3
Equipment electrical system protection
-
IPX4D
Flue gas max. temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
19.2
Weighted CO
mg/kWh
6.6
Type of appliance
C13 / C23 / C33 / C43 / C53 / C83 / B23p
/ B33p
Category
II2H3B/P
Summary of Contents for VICTRIX 26 2 I