Functioning anomaly signalled
Code
Flashing
Remote display
No ignition block
01
E01
Safety thermostat block (
overheating
), flue thermostat or flame
control anomaly
02
E02
NTC flow probe anomaly
05
E05
Domestic hot water NTC probe anomaly
(for instant boilers)
06
E06
Reset selector switch fault
08
E08
Calibration function active
(displayed only on CAR)
E09
No circulation
10
E10
Storage tank probe anomaly
(for boilers with storage tank)
12
E12
Configuration error
15
E15
Fan anomaly
16
E16
Parasite flame block
20
E20
Insufficient circulation
27
E27
CAR offline or not compatible anomaly
31
Low power supply voltage
37
Loss of flame signal
38*
* In case of connection with the Remote Control, the error is not shown on the boiler display.