26
IMER INTERNATIONAL S.p.A.
KOINE 35
Q1
Q2
Q5
Q4
Q6
Q10
Q9
Q11
Q3
Q8
Q7
THERMAL CUTOUT PROTECTION
- The water pump and compressor are protected by a
thermal cut-out housed inside the pressure switch connected
to the inverter panel. The mixer motor and the cell wheel
motor are protected at various levels and if any one of the
protection devices trips, this will be signalled on the display.
ERROR MESSAGES (SHOWN ON PANEL DISPLAY):
- The error messages are shown on the inverter panel
GLVSOD\ZKHQVSHFL¿FVLWXDWLRQVDULVH
- ERR 00: Fault module inverter
- ERR 01: Motor overtemperature
- ERR 02: Motor thermal cut-out
- ERR 03: Momentary overload of motor
- ERR 04: Thermal image of motor
- ERR 05: Under-voltage
- ERR 06: Over-voltage
- ERR 07: Water pump protection
- ERR 08: Excessive air loss
- ERR 09: Cell wheel motor blocked
- ""BLOC"": Motor pump blocked
- ""H2O"": Water pressure too low
- ""VOLT""
Note: Refer to the table
7URXEOHVKRRWLQJ
on page 27, for further
information.
12. OPERATION
- The hopper safety grille must be
¿WWHGDQGVHFXUHG
at all times.
Never place materials other than premixed dry materials in
the hopper.
- Opening of the mixing chamber causes shutdown of the
PDFKLQHPRYLQJSDUWV¿J)LUVWFORVHWKHPL[LQJFKDPEHU
and press the start pushbutton to start the machine.
:HDUVSHFL¿HGSURWHFWLYHGHYLFHVEHIRUHZRUNLQJRQ
the machine
Regulate the water to obtain the required consistency.
'LIIHUHQWGLDPHWHUVRIGHÀHFWRUDUHDYDLODEOHPP
WKHVPDOOHUGHÀHFWRUVHQDEOHLPSURYHGQHEXOLVDWLRQDQGWKHODUJHU
ones are more suited to materials with a larger particle size.
)RUVWDQGDUGSODVWHULQJPDWHULDOVWKHGHÀHFWRUZLWKPPKROH
(ref.9b) is used.
However, it is important to measure the distance of the nozzle
(ref.9c) from the outlet so that it is the same as the diameter of
WKHGHÀHFWRU¿J
If no water is delivered, the machine shuts down.
Before restarting the machine, identify the cause of the problem:
YDOYHFORVHGGHOLYHU\KRVHEHQWWDQNHPSW\FORJJHG¿OWHUUHI