Setting the Message Gap
F5
Message Gap defines the distance between the beginning of each messages when printing the same
message repeatedly on the same item.
1
1
Press SET-UP.
2
2
Press D for “D-Message Gap.”
3
3
Type the distance in inches or
centimeters between messages and
press ENTER.
Setting the Box Length
F6
The system has the ability to ignore photosensor signals after detecting the box. This feature is useful
when you observe the system printing between boxes or more than once per box. Setting an accurate
box length will prevent unwanted prints. Do not set the box length to be longer than the length of the
product: you can miss printing on the next box if it is following too closely.
1
1
Press SET-UP.
2
2
Press C for “C-Box Length.” The
display will prompt for distance.
3
3
Type in the box length in inches or
centimeters.
Message Gap:
0
00.4 inches
Box Length:
0
00.2 inches