MAINTENANCE
9VXE EN
3-26
WB-C310340
WB-C310350
Check the Fan Belt
•
The engine is hot immediately after stopping it. You may get burnt if you touch the
engine. Wait until each part cools down.
•
Stop the engine and keep the key of the starter switch in safe.
•
If belt tension is excessive, the bearings and
belt will be damaged earlier.
•
Replace the bolt if it has elongated and the
adjustment margin is lost.
•
Run the engine at high speed for 30 minutes
after the belt is replaced. Check and adjust belt
tension then.
1. Check
1) Push a point in the middle of the fan pulley and
generator at approximately 98 N (10 kg). The belt
tension is proper if the belt slacks by approximately
10 mm.
2) Replace the belt if the belt has cracks.
2. Adjustment
1) Loosen the bolt (1) and nut (2).
2) Turn the adjust bolt (3) to move the generator (3) so
that the belt slackens by approximately 10 mm.
3) Tighten the bolt and nut.
4) Replace the bolt if it has elongated and the adjustment
margin is lost.
Fan pulley
Crank pulley
Alternator pulley
Fan pulley
Adjust plate
Summary of Contents for 9VXE
Page 2: ......
Page 8: ...FOREWORD 9VXE EN 0 4 This page is intentionally left blank ...
Page 10: ...9VXE EN ...
Page 28: ...9VXE EN ...
Page 66: ...OPERATION 9VXE ENG 2 38 ...
Page 67: ...OPERATION 9VXE ENG 2 39 This page is intentionally left blank ...
Page 69: ...9VXE EN ...
Page 101: ...MAINTENANCE 9VXE EN 3 32 ELECTRIC SYSTEM DIAGRAM ...
Page 102: ...MAINTENANCE 9VXE EN 3 33 ...
Page 108: ...9VXE EN SPECIFICATIONS ...
Page 109: ...9VXE EN ...
Page 115: ...SPECIFICATIONS 9VXE EN 4 6 This page is intentionally left blank ...
Page 116: ...MINI EXCAVATOR 9VXE PUBLISHED JUNE 2012 IHIMER S p A ITALY ...
Page 117: ......
Page 118: ...IHIMER Spa 53037 San Gimignano Loc Cusona SI Italy info ihimer com www ihimer com ...