MAINTENANCE
9VXE EN
3-21
WB-C310270
WB-C310280
FUEL SYSTEM
Check Fuel Quantity and Refilling
1. Turn the engine key switch key to the ON position and
check the quantity of remaining fuel on the fuel gauge.
Fuel tank capacity: 8.8 L
2. Refill the tank with fuel through the filler port (1) if
remaining fuel is insufficient.
Clean the strainer (2) of the filler port (1) if it is dirty.
3. Tighten the cap after refilling. Lock it with the engine
key.
•
If fuel overflows or spills, it may cause a fire.
Wipe off spilt fuel completely.
•
If the strainer is dismounted and fuel is refilled,
the engine may become defective. Do not
dismount it.
•
Do not bring fire close to the engine.
•
If any other fuel than light oil, bad influences are
caused upon the engine, which may be
incapable of demonstrating its functions and
performances sufficiently. In addition, using
such fuel may cause engine failures or
accidents. Never use any other fuel than light
oil.
Defects caused by using any other fuel than
light oil is exempted from warranty.
Discharging Water from Fuel Tank
1. Open the drain plug at the bottom of the fuel tank to
discharge water and sediment before starting work.
2. Close the drain plug when clean fuel comes out.
Fuel gauge
Drain plug
Summary of Contents for 9VXE
Page 2: ......
Page 8: ...FOREWORD 9VXE EN 0 4 This page is intentionally left blank ...
Page 10: ...9VXE EN ...
Page 28: ...9VXE EN ...
Page 66: ...OPERATION 9VXE ENG 2 38 ...
Page 67: ...OPERATION 9VXE ENG 2 39 This page is intentionally left blank ...
Page 69: ...9VXE EN ...
Page 101: ...MAINTENANCE 9VXE EN 3 32 ELECTRIC SYSTEM DIAGRAM ...
Page 102: ...MAINTENANCE 9VXE EN 3 33 ...
Page 108: ...9VXE EN SPECIFICATIONS ...
Page 109: ...9VXE EN ...
Page 115: ...SPECIFICATIONS 9VXE EN 4 6 This page is intentionally left blank ...
Page 116: ...MINI EXCAVATOR 9VXE PUBLISHED JUNE 2012 IHIMER S p A ITALY ...
Page 117: ......
Page 118: ...IHIMER Spa 53037 San Gimignano Loc Cusona SI Italy info ihimer com www ihimer com ...