Mounting
Use suitable washers.
Tightening torque of the fixing screws: max. 1.8 Nm
Electrical connection
To protect the whole system (wiring and I/O module) the individual electric
circuits must be protected with max. 16A.
Input/output module CR2013
24
core colour
potential
operating voltage
red
10 ... 30 V DC
black
GND
CAN interface
white
CAN_H
blue
CAN_L
green
CAN_GND
M12 connector PIN
connection
1
sensor supply L+
3
sensor supply L-
4
signal input
(switch, sensor)
2
signal input
(analog sensor)
5
n. c.
1
3
4
2
5
M12 connector PIN
connection
4
switching output L+
3
external voltage -
5
n. c.
1
3
4
2
5
Wiring
Pin connection / inputs