EN
4 - HANDLING AND INSTALLATION
SIR-52-P/F
4 - Pag. 16 / 22
4.5
HYDRAULIC CONTROL UNIT - OIL LOADING
LUBRICATING OIL
- Remove cover (A).
- Loading should be carried out by filling
in lubricating oil of the following class:
C CKB 100. Quantity: 170 l.
Make sure oil is between the MAX. and
MIN. level.
INFORMATION
Perform this operation after
some hours have passed since
the bar feeder stop.In that way the oil may flow back towards the control unit.
HYDRAULIC OIL
- Remove plug B.
- To top it up, fill with hydraulic oil: type
class C HG 32 or equivalent. Quantity: 80
l.
Make sure oil is between the MAX. and
MIN. level.