EN
2 - INFORMATION FOR USE
KID 80 SIV
2 - Pag. 18 / 66
no. 1 Bar end adjustment
Defines the position where the bar feeder
should send the "bar end" signal to the
lathe.
This value is referred to point (F) (maximum
bar pusher feeding point), and corresponds
to the piece length plus the cutting tool
thickness.
A - Parameter 1
B - Subparameter 1
The "Bar End 1 Adjustment" subparameter can be used for two separate functions.
1) the subparameter sends an interface signal to the bar feeder-lathe (2nd Bar end);
2) the subparameter allows opening the additional bush;
3) The subparameter sends an interface signal to the bar feeder-lathe (prevents the
headstock from completing the return stroke).
INFORMATION:
Using the "Bar End 1 Adjustment" subparameter rules out the possibility for
one of the the above mentioned functions of being used simultaneously with the
other
1) the subparameter sends an interface signal to the bar feeder-lathe
Defines the position where the bar feeder should send
the Bar End Signal 1 to the lathe.
This value refers to point (F) (maximum bar pusher
feeding point), and is a higher length than value (A).
The lathe enters a subprogram corresponding to a new
machining cycle, where the length of the piece to be
machined is shorter than the one of the main program.
INFORMATION:
1
no.1 Bar end
adjustment
xxxx (mm)
(inches)
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
1
0
Bar end
adjustment 1
XXXX (mm)
(inches)