2 - INFORMATION FOR USE
KID 80 SIV
EN
2 - Pag. 29 / 66
no. 14 Pulse number
Defines the number of pulses that the
bar receives so as to simplify its feeding
into the lathe collet.
It is active in any point inside the
"pulse window".
Description of the phase order:
- the bar enters the pulse phase;
- the bar meets the obstacle (the
collet); the pulses start;
- the bar exits the pulse phase.
Subparameters for setting the pulse
window:
M - Pulse phase window start
referred to (C);
N - Pulse phase window end referred
to (I), the "collet entry slowdown"
(G) simultaneously ends.
INFORMATION
To prevent unnecessary machine stops, it
is recommended to enter a high value in
the subparameter (M).
INFORMATION
If the bar meets an obstacle before
entering the pulse window section, the
bar feeder goes into "ALARM" (15
Stationary position before pulses).
14
no. 14 Pulse
number
xx pulses
DEFAULT VALUE
PROGRAMMABL
E VALUE
KID
KID
A 20
/
M 400
/
N 20
/
Window start
pulses
(mm)
(inches)
Window end
pulses
(mm)
(inches)