2 - INFORMATION FOR USE
KID 80 SIV
EN
2 - Pag. 21 / 66
no. 2 Facing length
Defines the movement of the bar fore end
according to point (C) (facing point).
Both positive and negative values.
B - (positive value)
D - (negative value)
no. 3 Facing mode
Defines the facing operation.
0 - (UNTIL BAR STOP); once the bar
has exceeded the value defined in
parameter 2, it proceeds until bar limit
stop or until it reaches the tool.
1 - (IN POSITION); the bar is
positioned in the point defined in
parameter 2.
Subparameters:
B - Overrun admitted after I
C - Facing to limit stop (%Vmax)
D - Facing to limit stop (%Cmax)
2
no.2 Facing
length
xxxx (mm)
(inches)
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
1
0
3
no. 3 Facing
mode
xxxxxxxxxxx
DEFAULT VALUE
PROGRAMMABLE
VALUE
KID
KID
A
1 0/1
B
0 /
C
1 /
D
50 /