3 - INFORMATION FOR SET UP
KID 80 SIV
EN
3 - Pag. 25 / 26
3.10
GENERAL PARAMETERS: DESCRIPTION
no. 89 Fair demo
0 - inactive
1 - active.
To activate this mode, it is necessary to
set parameter 35 at 1, parameter 6 (for
example) at 200 mm, and parameter 85
"Bar Change" at 1.
no. 90 Wrong bar feeder phase
0 - (K37 active with closed guide
channels in manual mode).
During the "MANUAL" cycle, the bar
feeder goes into "ALARM" when
performing movements (for example
"guide channel opening"). The bar feeder
"WORKING" phase is lost and must be re-
established; the "BAR FEEDER WAITING"
message will be displayed.
1 - (Bar feeder in manual mode and
lathe in automatic mode).
At the first bar feeding signal, the bar
feeder goes into "ALARM" mode if it is in
manual mode.
WARNING - CAUTION
After
the
"MANUAL/AUTOMATIC" lathe signal is given, this safety is not activated if the
bar feeder is working in "MANUAL" mode from the lathe.
89
no. 89 Fair Demo
x
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
0
0/1
90
no. 90 Wrong bar
feeder phase
xxxxxxxxxxx
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
0
0/1