2 - INFORMATION FOR USE
KID 80 SIV
EN
2 - Pag. 55 / 66
3 - ERROR: THE BAR FAILS TO ENTER INTO THE COLLET
The bar has met the first obstacle in the pulse window as defined in parameter 14 (pulse
window start - pulse window end) and has exceeded the entry attempts as defined in the same
parameter (pulse number).
CAUSE SOLUTION
3
3 Error: bar fails
to enter into the
collet
The bar does not enter into the
collet or into the lathe bush.
Check the diameter of the bush.
If it is a shaped bar, check if the bar
entry kirving is correct on the rear part
of the collet.
If it is a shaped bar, check the spindle
rotation and if the pulse sequence is
correct.
The feeding speed and/or torque
are not suitable.
Check the speed (see parameter 12)
and/or the torque (see parameter 13).
4 - ERROR: GATE OPEN (S1008 Off)
Error: AT THE FIRST FEEDING STROKE START, THE SHORT FEED GATE IS OPEN.
CAUSE SOLUTION
4
4 Error: short feed
gate open
The short feed gate is jammed and
cannot be closed.
Make sure that there are no foreign
bodies (chips, remnants, fragments) in
the short feed gate movement area;
carry out the movement manually to
find any possible obstacles.
Operation failure of the solenoid
valve of the short feed gate closing.
Check the electromechanical operation
of the device.
Operation failure of the sensor,
which detects the short feed gate
closing.
Make sure that to the short feed gate
movement corresponds to the sensor
state change.