EN
2 - INFORMATION FOR USE
KID 80 SIV
2 - Pag. 44 / 66
no. 35 Fixed-piece feeding
0 - (AT THE LIMIT STOP). Carries out
the feeding to the bar limit stop.
1 - (AT FIXED VALUES). Carries out
the piece feeding, in accordance to the
value set in parameter 6.
2 - (AT FIXED VALUES AND THRUST
TO THE LIMIT STOP). Carries out the
piece feeding according to the value
set in parameter 6, stops at few
millimetres from the bar limit stop,
and then carries out another feeding
up to the bar limit stop, until the
FEEDING signal is active.
Parameter:
A - Fixed piece feeding
Subparameters:
B - Position
C - Speed
D - Acceleration
E - Deceleration
no. 36 K15 disabling
0 - (K15 ENABLED). Enables the warning at
every use of parameter 35 in position 1.
1 - (K 15 DISABLED). Disables the warning
at every use of parameter 35 position 1.
35
no. 35 Fixed piece
feeding
xxxxxxxxxx
DEFAULT VALUE
PROGRAMMABLE
VALUE
KID
KID
A
0 /
B
/ /
C
76200 /
D
100 /
E
100 /
36
no.36 K15 Disabling
xxxxxxxxxx
DEFAULT VALUE
PROGRAMMABLE
VALUE
K I D
K I D
1
1
Summary of Contents for KID 80
Page 2: ......
Page 4: ......
Page 11: ...1 BASE INFORMATION KID 80 SIV EN 1 Pag 5 15 ...
Page 22: ......
Page 105: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 17 26 ...
Page 114: ...EN 3 INFORMATION FOR SET UP KID 80 SIV 3 Pag 26 26 ...