6.8
AXIS CALIBRATION PROCEDURE
Foreword:
This procedure is aimed at optimizing the movements of the bar feeder axis. This procedure
should not be performed daily, but it is advisable to repeat it at regular intervals (recommended
time: once a month) to compensate any wear of the mechanical feeding units that could alter
the AXIS control operations.
Procedure:
Move the feeding carriage from its completely
backwards position in manual mode
, then
simultaneously press [Zero_Macchina_sx-dito]
and
for at least 2 seconds, until Offset appears
on the display. Now the operator may release the
buttons.
INFORMATION:
Before performing the above mentioned procedure make sure that the
mechanics have no clearances (e.g.: feeding belt not tensioned properly) and
that the zero axis sensor is positioned correctly (it shall not be too retracted).
Offset...