EN
8 - TROUBLES – CAUSES - SOLUTIONS
Elite112_220_Evo_SIII
8 - Pag. 2 / 2
8.1 GENERAL
FAILURES
TROUBLES CAUSES SOLUTIONS
The bar feeder cannot start
No power.
Check the electrical connection.
Open guard.
Close the guard.
Emergency systems on.
Disconnect the emergency devices.
Motor thermal circuit breaker
burnt.
Reset the thermal circuit breaker
with the special buttons.
The bar feeder has been reset
but the automatic cycle will not
start.
No lathe signal.
Check the electrical connection with
the lathe.
The pneumatic devices do not
respond to controls.
No air.
Check the air system.
The first feeding and feeding
are stopped unexpectedly.
Motor thermal circuit breaker
burnt.
Reset the thermal circuit breaker
with the special buttons.
8.2
FEEDING INTO COLLET – Failures
TROUBLES CAUSES SOLUTIONS
Bar fails to enter collet
Collet diameter not suitable
for bar diameter
Change collet
Excessive rag on bar rear end Trim rag before feeding
8.3
BAR FEEDING - Failures
TROUBLES CAUSES SOLUTIONS
Difficult bar introduction into
lathe spindle
Bar feeder not aligned with
lathe
Check and correct the alignment
Difficult bar introduction into
lathe collet
Excessive rag on bar fore end Trim rag before feeding
8.4
GUIDE CHANNEL IRREGULAR MOVEMENT - Failures
TROUBLES CAUSES SOLUTIONS
The guide channel closes on the
bar pusher.
Detected bar pusher position
inconsistent with the real bar
pusher position.
Encoder joint replacement. Contact
Iemca service department.