77
III.
OTHERS
III-1. How to use Button Camera (SG-110, SG-210, SG-310 model only)
1. Press [ENT] for 2 seconds to turn on the power.
2. Connect
IV-SGVA
with Button Camera through the port in the body “Connector
with Docking” .
3. Use [ ] and [ ]
◁
▷
to change
3.EXT CAM3: OFF to ON
. (“OPTION” -> 1.CAMERA
SET -> 3.EXT CAM3: OFF) (When not using internal camera(s), turn OFF 1.INT CAM1).
4. Use [ ] and [ ]
◁
▷
to change
3.EXT MIC: OFF to ON
. (“OPTION” -> 2.RECORD
SET -> 3. EXT MIC: OFF)
5. In the main menu, select “1.RECORD” and press [ENT] to record audio and video
of button camera.
6.
When removing button camera from
IV-SGVA
,
turn ON “1.INT CAM1”
(“OPTION” -> 1.CAMERA SET -> 1.INT CAM1: OFF)
and “2.INT MIC”
(“OPTION” ->
B.RECORD SET -> 2.INT MIC: OFF) to reactivate internal camera and microphone.
78
TROUBLESHOOTING GUIDE
z
IV-SGVA
shuts down its power for no reason automatically
The
IV-SGVA
automatically turns off the power or goes into the power-savings
mode if you don’t press any button for a certain amount of time (1-9 minutes). This
does not indicate malfunction of the system.
In “RECORD” and “TRANSMIT” modes,
IV-SGVA
turns off only the LCD, battery
status LAMP, and recording status LAMP to save the battery. But, in the rest of
the modes except for “RECORD” or “TRANSMIT”, it turns off the power
completely. Set the time to 0 to deactivate “AUTO POWER OFF” function.
Caution: To maximize the life of the battery, do not turn off “AUTO POWER
OFF” function.
z
Battery power fades quickly.
1. When you are not using the Bluetooth, set “
POWER
” to off from the menu
“BLUETOOTH”. (
IV-
SG
VA
-300310 only)
2. In the menu “OPTION”, select “SAVE BAT” from the menu “POWER SET” of the
menu “OTHERS”, and set on “SAVE BAT”.
z
If I connect the
IV-SGVA
with the adaptor, then the
IV-SGVA
turns on its
power automatically.
IV-SGVA
has a function
named, “automatic recovery function”, and it
automatically turns on its power when it is provided with external power sources.
If there is an electricity (a power) failure,
IV-SGVA
automatically starts to use the
power from its battery. But the
IV-SGVA
turns off its power, when it is not
provided with the power from the adaptor for a long time, and uses up the whole
battery. And as soon as the electricity is available to the
IV-SGVA
, it
automatically starts to charge the battery with electricity, and returns back to the
modes just before it turned off its power (“RECORD”, “TRANSMIT”, or to the initial
mode). This function is very useful when you have installed the
IV-SGVA
in the
remote places far away from you. In the case that you have installed the
IV-SGVA
in remote places, and there happens an electricity failure for some time and
the electricity gets available to the
IV-SGVA
again, then you have to go to where
the
IV-SGVA
is placed to turn it on, and to set it to the “RECORD” or