40
©2018 Integrated Device Technology, Inc
September 12, 2018
8A3xxxx Family Programming Guide
STATUS.IN2_MON_STATUS
Input 2 reference monitor status.
STATUS.IN1_MON_STATUS Bit Field Descriptions
Bit Field Name
Field Type Default Value
Description
IN1_FREQ_OFFS_LIM_ST
ICKY[6]
R/O
0
Frequency offset limit sticky bit.
Indicates that frequency offset limit was exceeded for input 1.
0 = no change
1 = live status changed
IN1_NO_ACTIVITY_STIC
KY[5]
R/O
0
No activity sticky bit.
Indicates that no activity was detected for input 1.
0 = no change
1 = live status changed
IN1_LOS_STICKY[4]
R/O
0
LOS sticky bit.
Indicates that loss of signal was detected for input 1.
0 = no change
1 = live status changed
RESERVED
N/A
-
This field must not be modified from the read value
IN1_FREQ_OFFS_LIM_LI
VE[2]
R/O
0
Frequency offset limit live status.
Indicates that the current frequency offset exceeds the limit for input 1.
0 = inactive
1 = active
IN1_NO_ACTIVITY_LIVE[
1]
R/O
0
No activity live status.
Indicates no activity on input 1.
0 = inactive
1 = active
IN1_LOS_LIVE[0]
R/O
0
LOS live status.
Indicates loss of signal on input 1.
0 = inactive
1 = active
Table 34: STATUS.IN2_MON_STATUS Bit Field Locations and Descriptions
Offset
Address
(Hex)
STATUS.IN2_MON_STATUS Bit Field Locations
D7
D6
D5
D4
D3
D2
D1
D0
00Ah
RESERVED[
7]
IN2_FREQ_
OFFS_LIM_
STICKY[6]
IN2_NO_AC
TIVITY_STIC
KY[5]
IN2_LOS_ST
ICKY[4]
RESERVED[
3]
IN2_FREQ_
OFFS_LIM_L
IVE[2]
IN2_NO_AC
TIVITY_LIVE
[1]
IN2_LOS_LI
VE[0]