FDX-S Series User Guide
115
Problem
Cause/Check item/Solution
Page
● Audio output
Audio is not being
output.
Ensure that audio output is turned on.
If there are multiple output connectors in the source device, check
the audio output setting of the source device.
-
Ensure that the input audio format is supported by the connected
sink device.
Typically, LCD monitors may not output 88.2 kHz or higher
sampling frequency of LPCM and compressed audio
(such as Dolby Digital, DTS, and other format).
In order to play a Blu-ray disc having compressed audio, check
the audio output setting of the source device.
The source device
’s audio signal characteristics can be managed
by the HDC
’s EDID configuration settings.
Ensure that DVI signal is not being output from the source device.
Ensure that the output mode is not set to DVI output.
If the EDID of the connected sink device cannot be obtained for
some reason, the FDX-S cannot determine the sink type. As a
result, audio may not be output. In such case, set
” to “ALWAYS1” or “ALWAYS2”.
Even though multi-
channel audio is
played, only
2-channel audio is
output
For multi-channel, change the EDID setting which is set to 2-
channel audio by default.
If the problem still cannot be solved, check if multi-channel audio
is output from the source device again, and then check the source
device settings.
Compressed audio
(such as Dolby
Digital, DTS) is not
output from the
source device.
Compressed audio input is set to OFF (EDID settings) by factory
default. If using compressed audio, change the EDID setting.
Check the audio output settings of the source device.
-
● Button operation
Buttons do not
operate.
Ensure that buttons are not locked.
When the FDX-S is powered on, it takes about 15 seconds to start
up. During the start-up process, all buttons are disabled.
-
● Communication command control
Control commands
cannot be issued
from PC to the
FDX-S.
Are the following items set correctly?
For RS-232C : Baud rate and data word length
For LAN
: IP address and subnet mask
When the FDX-S is powered on, it takes about 15 seconds to start
up. During the start-up process, communication command control
is disabled.
-
● WEB browser control
WEB browser cannot
be issued from PC to
the FDX-S.
Is the connection setting of the TCP port valid for the web
browser?