4 Power Supply and Power Supply Wiring
3-10
KW2D Series Smart RFID Reader User’s Manual
4.4 Power Supply Terminal Block Wiring Method
●
How to attach the wire
■
Stranded wires with ferrules or solid wire
1
Insert the wire straight to the back of the wire port, and then the wire will be connected.
2
After wiring, pull the wires lightly to make sure that the wire is properly connected.
Turn off the power before wiring.
•
Crimping dimensions of the terminal hole side (Maximum connectable crimping size) is W2.1 x H1.48mm.
Recommended crimping tool, refer to "5.3 Recommended Tools" on page 3-15.
•
Connect the ferrules to the terminal block so that the long side is horizontal as shown in the figure below.
Do not insert the ferrules in the vertical direction as shown in the figure below. The clamp and spring may
break and no longer function.
Warning
Warning