15
Response SE Combi -
Installation
INSTALLATION
13 PREPARING THE WALL
Note.
If the terminal is to be sited within 25-
40mm of a corner or vertical pipe then the hole
MUST be accurately cut and the rubber
weather seal trimmed around the groove
provided.
The terminal wall plate need not be fitted.
1.
Cut the flue hole (preferably with a 5"
core boring tool), ensuring that the hole is
square to the wall.
Both wall faces immediately around the
cut hole should be flat.
2.
Drill 4 holes with a 7mm (
1/4
") masonry
drill and insert the plastic plugs provided,
for the wall piping frame.
WARNING.
Ensure that, during the cutting operation, masonry falling
outside of the building does not cause damage or personal injury.
14 FITTING THE PIPING FRAME
Fit the wall mounting frame either:
a. Directly to the wall
z
z
z
z
z
Insert wall plugs.
z
z
z
z
z
Put the screws into the wall plugs and leave 10mm proud
z
z
z
z
z
Hang the frame onto the screws and tighten up.
or
b. Use stand-off brackets
(To allow pipework to be taken upwards).
z
z
z
z
z
Insert wall plugs.
z
z
z
z
z
Put the screws into the wall plugs and leave 10mm proud.
z
z
z
z
z
Fasten each bracket to the frame with the 6mm screws
and washers provided.
z
z
z
z
z
Hang the brackets and frame onto the screws and tighten
up.
Note.
If the clearances above and below the boiler are
less than the length of the pipes it will be necessary to
position the pipes behind the wall mounting plate BEFORE
the plate is screwed to the wall.
REAR FLUE OUTLET