INSTALLATION
The safety valve is located at the bottom LHS of the boiler.
1.
Using the pressure relief valve outlet pipe, nut and
olive from the hardware pack, assemble into safety
valve as shown.
2.
If access to the nut is difficult remove the socket screw
from inside of fitting and pull the valve from the pipe to
allow the piping nut to be tightened.
3.
Replace valve and tighten socket screw. The position
of the safety valve discharge pipe should be such that
any discharge of water or steam does not create a
hazard.
4.
Use the 90
0
compression elbow so the pipe is directed
towards the rear.
33 SAFETY VALVE DRAIN
35 FLUE EXTENSION DUCTS - continued
PACK D Flue extension duct kit contents.
34 FLUE EXTENSION DUCTS - For overall flue lengths greater than 600mm (23
5/8"
)
1. A
maximum
of 3 extension ducts (one suitably
cut) plus the standard flue duct may be used
together.
2.
Flue extensions of greater length than 1m (39")
should be supported with the bracket provided,
suitably adjusted - refer to Frame 34.
Note.
Side flue shown
GENERAL ARRANGEMENT
Use a maximum of 3m extended flue ONLY