36
Response SE Combi -
Installation
INSTALLATION
1. To check the temperatures:
a.
Select MONITOR mode by pressing the MODE button
until the decimal point after the first digit on the display
flashes.
The first digit now gives the step number and the last
2 the temperature.
b.
Select the required step number by pressing the
STEP button.
2. To change the temperature settings:
a.
Select PARAMETER mode by pressing the MODE
button until the decimal point after the first digit on the
display
shows steadily.
The first digit now gives the step number and the last
two the value of the setting
Note.
In this mode it is also possible to switch the boiler
on or off in either CH or DHW mode.
b.
Select the required step number by pressing the STEP
button.
c.
Reset the temperature to the required value by pressing
+ and - buttons.
d.
Store the new value by pressing the STORE button. The
display should flash twice.
e.
To return the control to the normal running STANDBY
mode press the RESET button.
f.
Refit the controls button cover plate.
WATER TEMPERATURES
The design water output temperatures are as follows:
Central Heating
82
0
C maximum
Domestic Hot Water
60
0
C maximum
These temperatures can be checked and settings changed (if required) as follows:
49 GENERAL CHECKS - continued
Step number
Temperature
o
C.
1
CH flow temp
o
C.
2
CH return temp
o
C.
3
DHW inlet temperature
o
C
4
Outside temp
o
C. (if fitted)
5
Maximum set value of CH flow temp
o
C
c.
To return the control to the normal running
STANDBY mode press the RESET button.
Stepnumber
Temperature
o
C.
1
Max DHW temp ( 40
o
to 60
o
C)
2
00
= DHW OFF
05
= DHW ON
3
00
= CH OFF
01
= CH ON
4
Max CH temp ( 20
o
to 82
o
C)
INST
ALLA