3
Response SE Combi -
Installation
Gas supply
2H
Gas Supply Connection
22mm copper
Inlet Connection
Domestic Hot Water
15mm copper
Outlet Connection
Domestic Hot Water
15mm copper
Flow Connection
Central Heating
22mm copper
Return Connection
Central Heating
22mm copper
Flue Terminal Diameter
100 mm
Maximum Working Pressure (Sealed Systems)
2.65 bar
Maximum Domestic Hot Water Inlet Pressure
10.0 bar
Minimum Domestic Hot Water Inlet Pressure
0.65 bar
Electrical Supply / Power consumption
230 V ~ 50 Hz. / 126 W
Fuse Rating
External : 3A Internal : F2A
Water content
Central Heating
2.2 litre
Domestic Hot Water
0.15 litre
Dry Weight
49Kg
Maximum Installation Weight
41Kg
Boiler Casing Size
Height
800 mm
Width
450 mm
Depth
300 mm
Maximum
DHW Input :
Nett CV
kW
25.1
(Btu/h)
(85 700)
Gross CV
kW
27.9
(Btu/h)
(95 200)
Gas Consumption
l/s
0.72
(ft
3
/h)
(91.5)
Maximum
DHW Output
kW
24.0
(Btu/h)
(81 900)
DHW Flow Rate at 35
o
C temp. rise. l/min
10.0
Burner Setting Pressure (HOT)
mbar
13.0
in. wg.
5.2
Seasonal efficiency (SEDBUK)*
[88.3]%
Table 1 - General Data
GENERAL
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross
or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different
calorific value:
a. FOR L/S
- divide the gross heat input (kW)
by the gross C.V. of the gas (MJ/m
3
)
b. FOR FT
3
/H
- divide the gross heat input
(Btu/h) by the gross C.V. of the gas (Btu/ft
3
)
Table 2 - Performance Data - Central Heating
Table 3 - Performance Data - Domestic Hot Water
Min.
Max.
Boiler Input :
Nett CV
kW
10.1
25.1
(Btu/h)
(34 500)
(85 700)
Gross CV
kW
11.2
27.9
(Btu/h)
(38 200)
(95 200)
Gas Consumption
l/s
0.29
0.72
(ft
3
/h)
(36.8)
(91.5)
Boiler Output :
70
o
C Mean Water Temp
kW
9.6
24.0
(Btu/h)
(32 800)
(81 900)
40
o
C Mean Water Temp
kW
10.9
25.7
(Btu/h)
(37 200)
(87 700)
Burner Setting Pressure
mbar
2.0
13.0
(HOT)
in. wg.
0.8
5.2
Key to symbols
IE
= Ireland
(Countries of
GB
= United Kingdom
destination)
PMS
= Maximum operating pressure of water
C13
= A room sealed appliance designed for connection via ducts to a horizontal
terminal, which admits fresh air to the burner and discharges the products
of combustion to the outside through orifices which, in this case, are
concentric. The fan is up stream of the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
*The value is used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by Gastec NV 0061.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.