TUNNEL MASTER JR MANUAL
Wash Configuration
40
Wash Settings (Continued)
Auto Pulse
Period
This is the rate in which you want the conveyor
to run when in Auto Pulse.
You should set this
value to 0 when the conveyor is running. Doing this
will automatically calibrate this setting based on
your conveyor speed. If you change conveyor
speeds, you should reset this.
Auto Pulse
Enter
Y
for yes,
N
for no if the user wishes the system
to simulate a pulse in the event of pulse switch failure.
Note: This feature will activate as soon as “Y” is
entered and the user hits save.
Invert Gate
Enter
Y
for yes,
N
for no, allows operator to decide if
logo switch is wired low or high. (Will vehicle break
continuous circuit or complete a circuit?)
Auto Gate Delay Enter the length in inches or pulses of estimated chain
travel, after a roller button is activated, before a vehicle
would normally activate the gate switch. This value
must be greater than 0.
Auto Gate
Enter
Y
for yes,
N
for no. This feature is used as a
back up for the Gate input. If the Gate input goes
down, you can turn this feature on. This will simulate
the measuring of the car. It will set every car length to
the value set for Max Car Length.
Roller Control
Enter
Y
for yes,
N
for no if one of the outputs will fire
the roller solenoid.
Entrance
Management
Enter Y for yes, N for no if you have a treadle switch
wired into Input 10.
Entrance Mgmt
Delay
Optional setting to be used with the Entrance
Management System. This value is the number of
seconds you want the roller output to delay before
firing.
Roller Locator
Enter Y for yes, N for no. When this option is set to
yes, the system will wait to fire the Roller Output until
the trailing edge of a signal is detected from Input 9.
Roller Interlock
Enter
Y
for yes,
N
for no. When this option is set to
yes, the system will not allow a roller to be fired
without a service being selected. This value should be
set to N if using the TMJ Interface.
Auto Roller
Enter
Y
for yes,
N
for no. When this option is set to
yes, as soon as you select a base service on a non-
stacking system, a roller will fire.
Panic Stop
Enter Y for yes if you have the panic stop wired into
the system, N for no if a Panic Stop is not installed.