The Relay Box Dip Switch Settings
Dip Switch Settings
The following picture and table will show the Relay Box Dip
switch and the various settings that may be used.
Helpful Tips
☺
For location of the Dipswitch refer to the previous Relay Box
picture on page 14. The “ON” position is always up. A 24 Output
Relay Box will ship as ADDR1. If you were to add a second
Relay Box to the system, it should be addressed as ADDR9.
The following picture shows the Relay Box door Dip switch.
Relay Box Dip
Switch
Switch Normal
Setting/Function
These are the dipswitch settings for normal operations.
Switch Setting
Function
1 OFF
Address
setting:
2 OFF
Address
setting
3 OFF
Address
setting
4 OFF
Address
Setting
1, 2, 3, 4 OFF
1 ON, 2, 3, 4 OFF
1 ON, 2, 3 OFF, 4 ON
1 & 3 ON, 2 & 4 OFF
1 ON, 2 OFF, 3, 4 ON
= Address 1
= Address 9
= Address 10
= Address 11
= Address 12
5
OFF
Baud Rate:
OFF = 9600
ON = 38,400
6
OFF
Up position allows access to Initialization Menu options
7 OFF
Pulse
Enhancement
8 OFF
Pulse
Enhancement
7 & 8 OFF
7 OFF, 8 ON
7 ON, 8 OFF
7 & 8 ON
Normal
2 Times
4 Times
8 Times