104
CONTROL COMMAND
1
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
19
20
21
14
18
14
Cmd. Sub cmd.
Data
Description
1A
05 0030
00
Send/read BW Popup (PBT) setting OFF
01
Send/read BW Popup (PBT) setting ON
0031
00
Send/read BW Popup (FIL) setting OFF
01
Send/read BW Popup (FIL) setting ON
0032
00
Send/read SSB/CW Synchronous Tuning
function OFF
01
Send/read SSB/CW Synchronous Tuning
function ON
0033
00
Send/read LSB selection for CW normal
side
01
Send/read USB selection for CW normal
side
0034
00
Send/read KEYER-Root selection for
keyer 1st menu
01
Send/read KEYER-SEND selection for
keyer 1st menu
0035
00
Send/read external keypad OFF
01
Send/read KEYER SEND selection for the
external keypad
0036
00
Send/read USB audio squelch OFF
(OPEN)
01
Send/read USB audio squelch ON
0037
0000 to
0255
Send/read USB modulation level
(0000=0% to 0255=100%)
0038
00
Send/read MIC selection for the modula-
tion input during DATA mode OFF
01
Send/read ACC selection for the modula-
tion input during DATA mode OFF
02
Send/read MIC+ACC selection for the
modulation input during DATA mode OFF
03
Send/read USB selection for the modula-
tion input during DATA mode OFF
0039
00
Send/read MIC selection for the modula-
tion input during DATA mode operation
01
Send/read ACC selection for the modula-
tion input during DATA mode operation
02
Send/read MIC+ACC selection for the
modulation input during DATA mode op-
eration
03
Send/read USB selection for the modula-
tion input during DATA mode operation
0040
00
Send/read CI-V transceive OFF
01
Send/read CI-V transceive ON
0041
00
Send/read CI-V selection for “USB” (COM
port) function
01
Send/read RTTY selection for “USB”
(COM port) function
0042
00
Send/read 300 bps selection for RTTY De-
code Baud rate
01
Send/read 1200 bps selection for RTTY
Decode Baud rate
02
Send/read 4800 bps selection for RTTY
Decode Baud rate
03
Send/read 9600 bps selection for RTTY
Decode Baud rate
04
Send/read 19200 bps selection for RTTY
Decode Baud rate
0043
00
Send/read Calibration marker OFF
01
Send/read Calibration marker ON
0044
0000 to
0255
Send/read reference frequency
(0000=0% to 0255=100%)
0045 see p. 107 Send/read SSB RX HPF/LPF setting
0046 00 to 10 Send/read SSB RX Tone (Bass) level
(00=–5 to 10=+5)
0047 00 to 10 Send/read SSB RX Tone (Treble) level
(00=–5 to 10=+5)
Cmd. Sub cmd.
Data
Description
1A
05 0048 00 to 10 Send/read SSB TX Tone (Bass) level
(00=–5 to 10=+5)
0049 00 to 10 Send/read SSB TX Tone (Treble) level
(00=–5 to 10=+5)
0050 see p. 107 Send/read SSB TX bandwidth for WIDE
0051 see p. 107 Send/read SSB TX bandwidth for MID
0052 see p. 107 Send/read SSB TX bandwidth for NAR-
ROW
0053 see p. 107 Send/read AM RX HPF/LPF setting
0054 00 to 10 Send/read AM RX tone (Bass) level
(00=–5 to 10=+5)
0055 00 to 10 Send/read AM RX Tone (Treble) level
(00=–5 to 10=+5)
0056 00 to 10 Send/read AM TX tone (Bass) level
(00=–5 to 10=+5)
0057 00 to 10 Send/read AM TX Tone (Treble) level
(00=–5 to 10=+5)
0058 see p. 107 Send/read FM RX HPF/LPF setting
0059 00 to 10 Send/read FM RX tone (Bass) level
(00=–5 to 10=+5)
0060 00 to 10 Send/read FM RX Tone (Treble) level
(00=–5 to 10=+5)
0061 00 to 10 Send/read FM TX tone (Bass) level
(00=–5 to 10=+5)
0062 00 to 10 Send/read FM TX Tone (Treble) level
(00=–5 to 10=+5)
0063 see p. 107 Send/read CW RX HPF/LPF setting
0064 see p. 107 Send/read RTTY RX HPF/LPF setting
0065
00
Send/read Normal selection for contest
number style
01
Send/read “190
→
ANO” selection for con-
test number style
02
Send/read “190
→
ANT” selection for con-
test number style
03
Send/read “90
→
NO” selection for contest
number style
04
Send/read “90
→
NT” selection for contest
number style
0066
01
Send/read M1 selection for count up trig-
ger channel
02
Send/read M2 selection for count up trig-
ger channel
03
Send/read M3 selection for count up trig-
ger channel
04
Send/read M4 selection for count up trig-
ger channel
0067
0001 to
9999
Send/read present number
(0001=1 to 9999=9999)
0068
0000 to
0255
Send/read CW sidetone gain
(0000=0% to 0255=100%)
0069
00
Send/read CW sidetone gain limit OFF
01
Send/read CW sidetone gain limit ON
0070 01 to 60 Send/read CW keyer repeat time
(01=1 sec. to 60=60 sec.)
0071
00
Send/read Normal selection for message
display
01
Send/read Message selection for message
display
0072 28 to 45 Send/read CW keyer dot/dash ratio
(28=1:1:2.8 to 45=1:1:4.5)
0073
00
Send/read 2 msec. selection for Rise time
01
Send/read 4 msec. selection for Rise time
02
Send/read 6 msec. selection for Rise time
03
Send/read 8 msec. selection for Rise time