Firmware update
The transceiver displays its firmware version
information after turning power ON, if the opening
message screen indication capability is ON. (p. 135)
q
Copy the downloaded firmware data into the “IC-
7600” folder of the USB-Memory.
• The USB-Memory must have been formatted by the
IC-7600.
w
Insert the USB-Memory into the [USB] (A)
connector on the front panel.
e
Push
[EXIT/SET] several times to close any multi-
function screens, if necessary.
r
Push
[SET] (F-6) to select the set mode menu
screen.
t
Push
[USB] (F-6) to select the USB Memory set
menu.
y
Hold down
[FIRM UP] (F-3) for 1 second.
u
Read the displayed precaution carefully.
• Push
[
Y
] (F-1)
or
[
Z
] (F-2) to scroll the display.
• Push
[CANCEL] (F-6)
to cancel the firmware updating.
i
After you read and understand all of the
precautions, push
[OK] (F-5).
•
[OK] (F-5)
appears only following the precautions.
• Push
[CANCEL] (F-6)
to cancel the firmware updating.
o
Push
[
Y
] (F-2) or [
Z
] (F-3) to select the firmware
file, then push
[FIRM UP] (F-4).
!0
Read the displayed precautions carefully.
!1
If you agree, hold down
[OK] (F-5) for 1 second to
start the firmware update.
• Push
[CANCEL] (F-6)
to cancel the firmware updating.
!2
While loading the firmware from the USB-Memory,
the dialog to the right is displayed.
175
14
UPDATING THE FIRMWARE
F-1
F-2
F-5
F-6
EXIT/SET
USB
SET
CANCEL
DIR/FILE
OK
F-4
FIRM UP
F-3
FIRM UP
[USB] (A)
/
/
/
/
/