![Icom IC-7200 Instruction Manual Download Page 77](http://html2.mh-extra.com/html/icom/ic-7200/ic-7200_instruction-manual_3602265077.webp)
72
10
SET MODE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Key speed
(CW mode)
This item adjusts the CW key speed. The key speed can
be selected from 6 to 60* wpm.
* 39, 43, 45, 47, 49, 51, 53, 55, 56, 58 and 59 cannot be
selected.
20 WPM (default)
CW pitch
(CW mode)
This item adjusts the CW receive pitch. The pitch can be
selected from 300 to 900 Hz in 10 Hz steps.
600 Hz (default)
Side tone level
(CW mode)
This item adjusts the CW side tone level from 0% to
100% in 1% steps.
30% (default)
Side tone level limit
(CW mode)
Turn the CW side tones output level limiting capability
ON and OFF.
When this item is set to ON, the CW side tone is linked to
the
[AF]
control until rotation of the
[AF]
control reaches
to the specified level—further rotation will not increase
the volume of the CW side tones.
on : CW side tone level is limited with the
[AF]
control.
oF : CW side tone level is linked to the
[AF]
control.
ON (default)
Twin peak filter
(RTTY mode)
This item turns the twin peak filter ON or OFF.
on : Twin peak filter is ON.
oF : Twin peak filter is OFF.
NOTE:
The RTTY mark frequency (2125 Hz) and shift
width (170 Hz) are automatically set when the twin
peak filter is ON.
OFF (default)
RTTY mark tone
(RTTY mode)
This item selects the RTTY mark frequency. There are 3
selectable values: 1275, 1615 and 2125 Hz.
NOTE:
2125 Hz is automatically set when the twin
peak filter is ON.
2125 Hz (default)