-18-
iCharger Synchronous Balance Charger/Discharger 1010B/106B
Data save/load program
The
iCharger
has a storage and load program for your convenience. This feature can store up to 10 battery
datasets by number. Each dataset represent the individuals settings for a particular set of batteries. Datasets
can be reloaded for charging or discharging to save having to re-enter all the parameter values again by
hand.
To set a parameter value press
Start/Enter
to make it blink and then change the value with
Inc
or
Dec
.
Data save program
Data load program
Warning and error in formation
The
iCharger
incorporates a wide range of protection and alarm functions to monitor the operation of the
charger. This includes verifying the internal state and the condition of its electronics. In the case of any error
being detected the screen displays the error cause and the charger generates 3 beeps. If the error occurs
during a charging, discharging or cycling process the error message and termination data will appear
alternately.
This screen displays the data save program
Set the target memory number in the lower right corner. Press
Start/Enter
for more than 3 seconds to start the process.
Storage number: 0 – 9
Storing all of the current data into the specified memory location.
This screen displays the data load program.
Set the source memory number in the lower right corner. Press
Start/Enter
for more than 3 seconds to start the process.
Memory location number: 0 – 9
Load all parameters values from the selected location.
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
Save settings
Save settings
Save settings
Save settings
Start/Enter
Batt type
stop
SAVE SETTINGS
SAVE SETTINGS
SAVE SETTINGS
SAVE SETTINGS
Number: 0
Number: 0
Number: 0
Number: 0
Start/Enter
>3 seconds
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
PROGRAM SELECT
Load settings
Load settings
Load settings
Load settings
Save...
Save...
Save...
Save...
Start/Enter
Batt type
stop
LOAD SETTINGS
LOAD SETTINGS
LOAD SETTINGS
LOAD SETTINGS
Number: 0
Number: 0
Number: 0
Number: 0
Load...
Load...
Load...
Load...
Start/Enter
>3 seconds
When an error has been reported press
Batt type/Stop
to return to the
main menu. Press
Inc
or
Dec
to check the parameter value related to
the error. For example in the case of a temperature error you can check the
temperature that triggered the error.
Press
Start/Enter
to return to the error
message screen.
-
Dec
+
Inc
-
Dec
+
Inc
Termination at
Termination at
Termination at
Termination at
017:23 01245mAh
017:23 01245mAh
017:23 01245mAh
017:23 01245mAh
Termination
time
Termination
power
Summary of Contents for 1010B