-21-
iCharger Synchronous Balance Charger/Discharger 1010B/106B
Battery type
Cell count
Rated voltage (V)
Charge current (A)
1010B / 106B
Discharge current (A)
1010B / 106B
1
1.20
10 / 10
7 / 7
2
2.40
10 / 10
7 / 7
3
3.60
10 / 10
7 / 5.6
4
4.80
10 / 10
6.3 / 4.2
5
6.00
10 / 10
5.0 / 3.3
6
7.20
10 / 10
4.2 / 2.8
7
8.40
10 / 10
3.6 / 2.4
8
9.60
10 / 10
3.1 / 2.1
9
10.80
10 / 10
2.8 / 1.9
10
12.00
10 / 10
2.5 / 1.7
11
13.20
10 / 10
2.3 / 1.5
12
14.40
10 / 10
2.1 / 1.4
13
15.60
10 / 10
1.9 / 1.3
14
16.80
10 / 10
1.8 / 1.2
15
18.00
10 / 10
1.7 / 1.1
16
19.20
10 / 9.4
1.6 / 1.0
17
20.40
9.8 / 8.8
1.5 / 1.0
18
21.60
9.3 / --
1.4 / --
19
22.80
8.8 / --
1.3 / --
20
24.00
8.3 / --
1.3 / --
21
25.20
7.9 / --
1.2 / --
22
26.40
7.6 / --
1.1 / --
23
27.60
7.2 / --
1.1 / --
24
28.80
6.9 / --
1.0 / --
NiCD/NiMH
25
30.00
6.7 / --
1.0 / --
1
2
10.0 / 10.0
7.0 / 7.0
2
4
10.0 / 10.0
7.0 / 5.0
3
6
10.0 / 10.0
5.0 / 3.3
4
8
10.0 / 10.0
3.8 / 2.5
5
10
10.0 / 10.0
3.0 / 2.0
6
12
10.0 / 10.0
2.5 / 1.7
7
14
10.0 / 10.0
2.1 / 1.4
8
16
10.0 / 10.0
1.9 / 1.3
9
18
10.0 / 10.0
1.7 / 1.1
10
20
10.0 / 9.0
1.5 / 1.0
11
22
9.1 / 8.2
1.4 / 0.9
12
24
8.3 / 7.5
1.3 / 0.8
13
26
7.7 / --
1.2 / --
14
28
7.1 / --
1.1 / --
15
30
6.7 / --
1.0 / --
16
32
6.3 / --
0.9 / --
17
34
5.9 / --
0.9 / --
Pb
18
36
5.6 / --
0.8 / --
Summary of Contents for 1010B