-6-
iCharger Synchronous Balance Charger/Discharger 1010B/106B
Keyboard basics
1. Go to the main menu, press the
Inc
button or the
Stop/Batt type
button
to go down, and press the
Dec
button to go up: press the
Start/Enter
button to enter a sub-menu.
2. In a sub-menu, press
Start/Enter
to blink the chosen item, and then alter the value with
Inc
or
Dec.
With nothing blinking you can go to the sub-menu below with
Inc
and above with
Dec
. Press
Stop/Batt type
to go back to the previous screen.
3. In some sub-menus, press and hold
Start/Enter
for more than 3 seconds to start the process, such as
starting charging or discharging.
4. During the charging/discharging process you can terminate the process at any time by pressing
Stop/Batt type
and check the attached information with
Inc
or
Dec
. Press
Start/Enter
to go back to
the main information screen.
5. During the discharge process, press
Start/Enter
to alter the discharge current. When the discharge
current blinks, press
Inc
to increase it or
Dec
to decrease it, then press
Start/Enter
to confirm the
change.
6. Press
Stop/Batt type
for more than 3 seconds to start the display of the active test information as per
the following diagram.
Present testing information
:
:
:
:
7.
Reset to Defaults
function. Press
Stop/Batt type
and
Start/Enter
together for more than 3 seconds to
obtain this display:
Press
Start/Enter
to reset all values to the system-default settings.
Standard battery parameters
LiPo
LiIo
LiFe
NiCd
NiMH
Pb
Nominal voltage
3.7 V/cell
3.6 V/cell
3.3 V/cell
1.20 V/cell
1.20 V/cell
2.0 V/cell
Max. charge voltage
4.2 V/cell
4.1 V/cell
3.6 V/cell
1.60 V/cell
1.60 V/cell
2.45 V/cell
Storage voltage
3.85 V/cell
3.75 V/cell
3.3 V/cell
n/a
n/a
n/a
Allowable fast charge
current
≤ 1C
≤ 1C
≤ 4C
1C –
2C
1C –
2C
≤ 0.4C
Min. discharge voltage
cut-off level
≥ 3.0 V/cell ≥ 2.5 V/cell ≥ 2.0 V/cell ≥ 0.85V/cell ≥ 1.0 V/cell ≥ 1.75V/cell
NOTE:
Be very careful to choose the correct voltage for different types of battery otherwise you may cause
damage to the batteries. Incorrect settings could cause the cells to vent, burn or explode leading to injury or
loss of property.
In the parameter setting chapter that follows the screen diagram on the left shows the system’s default
setting.
In this display the output voltage is the idle voltage measured at the
output terminals (that is, the voltage of the connected battery pack).
(second screen on 1010B only)
Individual cell voltage from
the balance port.
Resume defaults?
Resume defaults?
Resume defaults?
Resume defaults?
CONFIRM (
CONFIRM (
CONFIRM (
CONFIRM (ENTER)
ENTER)
ENTER)
ENTER)
Vi11.94V Int30
Vi11.94V Int30
Vi11.94V Int30
Vi11.94V Int30℃
℃
℃
℃
Vo 8.23V Ext25
Vo 8.23V Ext25
Vo 8.23V Ext25
Vo 8.23V Ext25℃
℃
℃
℃
Output
Volt.
Input
Volt.
Int.
Temp.
Ext.
Temp.
Inc
/
Dec
1:4.11 4.12
1:4.11 4.12
1:4.11 4.12
1:4.11 4.12 ----
----
----
----
4:
4:
4:
4:----
----
----
----
----
----
----
----
----
----
----
----
7:
7:
7:
7:----
----
----
----
----
----
----
----
----
----
----
----
A:
A:
A:
A:----
----
----
----
Inc
Dec
Summary of Contents for 1010B
Page 1: ......