Attention:
v
Do not use excessive force when pressing the microprocessor into the
socket.
v
Make sure that the microprocessor is oriented and aligned correctly with
pin number 1 in the socket before you try to close the
microprocessor-release lever. The following illustration shows the
alignment marks for both microprocessors and sockets.
Microprocessor 2
Microprocessor 1
Microprocessor
socket 2
Microprocessor
socket 1
Alignment marks
Alignment marks
d. Carefully close the microprocessor-release lever to secure the
microprocessor in the socket.
9. Install a heat sink on the microprocessor:
a. Remove the protective film from the bottom of the heat sink.
Notes:
1) Do not set the heat sink down after you remove the protective film.
Heat sink
Thermal grease
2) Do not touch the thermal grease on the bottom of the heat sink.
Touching the thermal grease will contaminate it. If the thermal grease
on the microprocessor or heat sink becomes contaminated, contact
your service technician.
b. Align and place the heat sink on top of the microprocessor (grease side
down) in the retention bracket. Press firmly on the heat sink.
c. Secure the heat sink to the microprocessor by tightening the captive
screws. Alternate between the two captive screws in the heat sink while
tightening them.
Attention:
Alternate the tightening of the two captive screws to prevent
damage to the microprocessor. Ensure that the screws are completely
tightened (until they stop); otherwise, damage to the microprocessor will
occur.
10. Close the cover on the air-baffle assembly.
11. If you have other options to install or remove, do so now; otherwise, go to
“Installing the server bezel and left-side cover (tower model)” on page 96 or
“Installing the server bezel and top cover (rack configuration)” on page 99.
Chapter 4. Customer replaceable units
83
Summary of Contents for xSeries 235
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 183: ...Appendix B Related service information 173...
Page 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ...Appendix B Related service information 175...
Page 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 187: ...Appendix B Related service information 177...
Page 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Related service information 179...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 201: ...Appendix B Related service information 191...
Page 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201...
Page 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 213: ......
Page 214: ...Part Number 59P6524 1P P N 59P6524...