Note:
See “System” on page 156 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
180-XXX-003
(Failed system board LED
test)
v
System board
180-XXX-005
(Failed SCSI backplane LED
test)
1.
SCSI backplane
2. SCSI backplane cable
3. System board
201-XXX-0NN
(Failed memory test.)
1.
DIMM Location slots 1-6 where
nn
= DIMM location.
Note:
nn
1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4; 5=DIMM
5; 6=DIMM 6.
2. System board
201-XXX-999
(Multiple DIMM failure, see
error text)
1.
See error text for failing DIMMs.
2. System board.
202-XXX-001
(Failed system cache test)
1.
VRM 1
2. Microprocessor 1
202-XXX-002
(Failed system cache test)
1.
VRM 2
2. Microprocessor 2
206-XXX-000
(Failed diskette drive test)
1.
Cable
2. Diskette drive
3. System board
215-XXX-000
(Failed IDE CD-ROM drive
test)
1.
CD-ROM drive cables
2. CD-ROM drive
3. System board
217-198-XXX
(Could not establish drive
parameters)
1.
Check cable and termination.
2. SCSI backplane.
3. Hard disk.
217-XXX-000
(Failed BIOS hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk 1
217-XXX-001
(Failed BIOS hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk 2
217-XXX-002
(Failed BIOS hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk 3
217-XXX-003
(Failed BIOS hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk 4
217-XXX-004
(Failed BIOS hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk 5
217-XXX-005
(Failed BIOS hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array
v
Hard disk 6
Chapter 6. Symptom-to-FRU index
133
Summary of Contents for xSeries 235
Page 1: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 2: ......
Page 3: ...xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide ERserver...
Page 34: ...24 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 50: ...40 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 134: ...124 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 164: ...154 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 170: ...160 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 183: ...Appendix B Related service information 173...
Page 184: ...174 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 185: ...Appendix B Related service information 175...
Page 186: ...176 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 187: ...Appendix B Related service information 177...
Page 188: ...178 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 189: ...Appendix B Related service information 179...
Page 190: ...180 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 200: ...190 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 201: ...Appendix B Related service information 191...
Page 202: ...192 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 206: ...196 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 211: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix C Notices 201...
Page 212: ...202 xSeries 235 Type 8671 Hardware Maintenance Manual and Troubleshooting Guide...
Page 213: ......
Page 214: ...Part Number 59P6524 1P P N 59P6524...