v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
Invalid
Fan
configuration
Replace
any
missing
or
failed
fans.
IP
address
of
default
gateway
modified
from
x.x.x.x
Information
only
IP
address
of
network
interface
modified
from
x.x.x.x
Information
only
IP
subnet
mask
of
network
interface
modified
from
x.x.x.x
Information
only
Loader
Watchdog
Triggered
1.
Reconfigure
the
loader
watchdog
timer
to
be
a
higher
value
(twice
the
normal
operating-system
boot
time).
See
the
Remote
Supervisor
Adapter
II
SlimLine
and
Remote
Supervisor
Adapter
II
User’s
Guide
for
information.
2.
Install
the
Remote
Supervisor
Adapter
II
SlimLine
device
driver
for
the
operating
system.
3.
Disable
the
loader
watchdog.
See
the
Remote
Supervisor
Adapter
II
SlimLine
and
Remote
Supervisor
Adapter
II
User’s
Guide
.
4.
Check
the
integrity
of
the
installed
operating
system.
5.
Reinstall
the
operating
system
with
the
applicable
device
drivers.
Machine
check
asserted
1.
Reseat
the
memory
card.
2.
Replace
the
memory
card.
Machine
check
asserted
-
SPINT,
North
Bridge
Information
only,
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
-
SPINT,
PCI
Bridge
A
Information
only.
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
-
SPINT,
PCI
Bridge
B
Information
only.
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
-
SPINT,
Remote
CheckStop
Information
only.
Just
an
indication
of
who
reported
the
SPINT
first.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Remote
Node,
Link
1
Information
only.
The
machine
check
was
reported
by
the
node
connected
to
scalability
port
1.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Remote
Node,
Link
2
Information
only.
The
machine
check
was
reported
by
the
node
connected
to
scalability
port
2.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Remote
Node,
Link
3
Information
only.
The
machine
check
was
reported
by
the
node
connected
to
scalability
port
3.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Scalability
1.
Reseat
the
scalability
cables
and
microprocessor
board.
2.
Replace
the
scalability
cables
3.
Replace
the
scalability
cartridge
assembly.
4.
Replace
the
microprocessor
board.
Machine
check
asserted
for
Card
or
Link
-
SPINT,
Quad
Bus
A
1.
Reseat
microprocessor
1
and
2.
2.
Replace
microprocessor
1
or
2.
3.
Replace
the
microprocessor
board.
96
IBM
System
x3800
Type
8865:
Problem
Determination
and
Service
Guide
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 195: ......
Page 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...