v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
message
Action
POST
reporting
memory
event:
DIMM
Disabled
-
Failed
POST/BIOS
Memory
Test.
Chassis
Number
=
X.
Memory
Card
=
Y.
Memory
DIMM
=
Z.
1.
Reseat
the
DIMM.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
POST
reporting
memory
event:
DIMM
Disabled
-
Failed
ECC
Test.
Chassis
Number
=
X.
Memory
Card
=
Y.
Memory
DIMM
=
Z.
1.
Reseat
the
DIMM.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
POST
reporting
memory
event:
DIMM
Disabled
-
Failed
ECC
Test.
Chassis
Number
=
X.
Memory
Card
=
Y.
Memory
DIMM
=
Z.
1.
Reseat
the
DIMM.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
Unknown
SERR/PERR
detected
on
PCI
bus
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Address
of
special
cycle
DPE
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Master
read
parity
error
on
PCI
primary
Chassis#=4
Slot#=2
Bus#=3
Dev.ID=0xaa99
Vend.ID=0xccbb
Status=0xeedd
DevFun#=0xff
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Received
target
parity
error
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Chapter
2.
Diagnostics
35
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 195: ......
Page 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...