Error
code
Description
Action
035-002-0nn
ServeRAID
interface
timeout.
1.
Make
sure
that
the
ServeRAID
controller
is
configured
correctly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
see
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
ServeRAID
controller
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-253-0nn
ServeRAID
controller
0nn
initialization
failure;
0nn
=
the
controller
number.
1.
Make
sure
that
the
ServeRAID
controller
is
configured
correctly.
See
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
ServeRAID
controller
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-253-s99
RAID
adapter
initialization
failure.
1.
Reseat
the
following
components:
a.
ServeRAID
adapter
b.
SAS
hard
disk
drive
backplane
cable
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-254-0nn
Setup
error;
unable
to
allocate
memory
to
run
test.
Check
the
system
resources
and
make
more
memory
available
(see
then,
run
the
test
again.
035-255-0nn
Internal
error.
1.
Reseat
the
SAS
hard
disk
drive
backplane
cable.
2.
Replace
the
SAS
hard
disk
drive
backplane.
035-260-0nn
System
to
controller
interface
failure.
1.
Reseat
the
following
components:
a.
ServeRAID
adapter
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-265-0nn
Adapter
Communication
error.
1.
Update
the
RAID
controller
firmware
(see
2.
Reseat
the
RAID
controller.
3.
Replace
the
RAID
controller.
Chapter
2.
Diagnostics
77
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 195: ......
Page 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...