Error
message
Action
PCI
Bus
Invalid
transaction
PM/DR
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI
Bus
Invalid
transaction
PS/DW
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI
Bus
DMA
write
command
FIFO
parity
error
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI
Secondary
Status
Register
Dump
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI
Secondary
Status
Register
Dump
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI
to
PCI
Bridge
Discard
Timer
Error
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
SMI
handler
reporting
Memory
Mirroring
Failover
Occurred.
Running
from
mirrored
image.
Note:
This
message
immediately
follows
an
uncorrectable
memory
error.
1.
Reseat
the
DIMM
or
memory
card.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM
or
memory
card.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
SMI
handler
reporting
Processor
Event:
Unrecoverable
error.
Chassis
Number
=
X.
Processor
ID
=
Y.
(Trained
service
technician
only)
Replace
the
microprocessor.
Chapter
2.
Diagnostics
45
Summary of Contents for x3800 - System - 8865
Page 1: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 28: ...12 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 122: ...106 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 130: ...114 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 182: ...166 IBM System x3800 Type 8865 Problem Determination and Service Guide...
Page 195: ......
Page 196: ...Part Number 31R1860 Printed in USA 1P P N 31R1860...