5.
When you have returned to the command prompt, define the static routes
used for replication. Enter the command:
./ptconfig -staticRoutes <enter>
The message below displays:
Gathering System information [ Done ]
The auto-detected system information displays. For example:
Table 36. Example auto-detected system information
ID
Target Network
Address
Target Netmask
Local Gateway
Address
1
10.11.194.0
255.255.255.0
10.11.195.1
2
10.11.196.0
255.255.255.0
10.11.197.1
Important:
This information is only an example. The information that
displays will be specific to your system, and will be different.
Followed by the Available Options prompt:
Available Options:
==================
(a)dd a new record
(e)dit a record
(d)elete a record
(c)ommit changes
(q)uit
Please Choose (a,e,d,c,q):
6.
Type:
a <enter>
You are prompted to enter information for the first destination (target - eth7)
server and the local network.
Attention:
Do not configure the replication ports Eth7 and Eth11 on the
same subnet as the external LAN port Eth0. Doing so may cause replication
errors.
7.
At each prompt, type the requested information and then press <enter>:
Attention:
In this step, the term "target" refers to the remote node's network
address and netmask (not necessarily the replication "target" server for this
entry.)
Please provide the following information:
Target Network Address:
(starting network address) (for example: 10.11.194.0)
Target Network Netmask:
(for example: 255.255.255.0)
Local Gateway Address:
(the gateway IP address of the server you are currently configuring) (for
example: 10.11.195.1)
A summary displays:
Table 37. Example summary for first server and local network
ID
Target Network
Address
Target Netmask
Local Gateway
Address
1
10.11.194.0
255.255.255.0
10.11.195.1
104
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide
|
|
|
|
|
|
Summary of Contents for System Storage TS7650G 3958 DD4
Page 2: ......
Page 7: ...Russia Electromagnetic Interference EMI Class A Statement 189 Index 191 Contents v...
Page 8: ...vi IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 10: ...viii IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 12: ...x IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 16: ...xiv IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 30: ...xxviii IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 38: ...xxxvi IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 44: ...6 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 46: ...8 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 54: ...16 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 89: ...Figure 20 Clustered TS7650G power cabling Chapter 4 Installing the TS7650G hardware 51...
Page 120: ...82 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 148: ...110 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 150: ...112 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 156: ...118 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 172: ...134 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 192: ...154 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 198: ...160 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 210: ...172 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 220: ...182 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 228: ...190 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide...
Page 231: ......
Page 232: ...Part Number 46X6052 Printed in USA or Mexico GC53 1154 09 1P P N 46X6052...