Figure 59. Drive assembly
1
Disk drive
2
Online indicator
3
Fault indicator
4
Release latch
5
Drive latch toes
6
Drive carrier
Procedure
1. Read all the available safety information.
2. Remove the cover, as described in “Removing the top cover: 2077-92F ” on page 42.
3. Locate the empty drive slot to receive the new drive or that contains the faulty drive that you want to
replace.
Note: When a drive is faulty, the amber fault indicator is lit (
3
in Figure 59 on page 60). Do not
replace a drive unless the drive fault indicator is on or you are instructed to do so by a fix procedure.
A label on the enclosure cover (Figure 60 on page 60) shows the drive locations in the enclosure.
The drive slots are numbered 1-14 from left to right and A-G from the back to the front of the
enclosure.
Figure 60. Drive locations in a 5U expansion enclosure
The drive slots must be populated sequentially, starting from the back-left corner position (slot 1,
grid A1). Sequentially install the drive in the slots from left to right and back row to front. Always
complete a full row before you install drives in the next row. For example, in Figure 61 on page 61,
the drives are installed correctly. Drives are installed in slots 1 -14 of row A and the installation
continues in slot 15 in row B.
60 Storwize V5000 Gen2: Quick Installation Guide
Summary of Contents for Storwize V5000 Gen 2 Series
Page 1: ...IBM Storwize V5000 Gen2 Quick Installation Guide IBM...
Page 5: ...Index 149 v...
Page 6: ...vi...
Page 156: ...130 Storwize V5000 Gen2 Quick Installation Guide...
Page 164: ...138 Storwize V5000 Gen2 Quick Installation Guide...
Page 166: ...140 Storwize V5000 Gen2 Quick Installation Guide...
Page 168: ...142 Storwize V5000 Gen2 Quick Installation Guide...
Page 177: ......
Page 178: ...IBM...