Table 27. Other expansion enclosure parts (continued)
FRU Part
Number
Description
Comments
01LJ607
Enclosure
Note: Replaces enclosure FRU P/N
01LJ112.
Includes the drive board, signal
interconnect board, and internal power
cables, in an otherwise empty enclosure.
39M5388
16A power cord C19/C20 2 m
Connecting Ethernet cables to the node canisters
The control enclosures have several Ethernet ports on the rear of each node canister. The ports provide
access to system management facilities and can also provide iSCSI connectivity. The number of ports and
their initial function differ across each system model.
Procedure
To install the Ethernet cables, complete the following steps.
1. If you have a Storwize V5010 or Storwize V5020 system, complete the following steps.
a) Identify the location and function of the Ethernet ports on your system; refer to Figure 125 on page
120 and Figure 126 on page 121.
• Port 1 can be used to provide Ethernet connections; in the figures, port 1 is identified by the
green cable.
• Port 2 serves as the technician port when the system is initially set up or when service is needed.
In the figures, port 2 is identified by the blue cable. After the system initializes, port 2 can also be
used for iSCSI connectivity or IP replication.
Note: Do not connect port 2 to a network switch until the system initialization or service is
complete. After the system initializes, the technician port is automatically disabled and port 2 can
be used for Ethernet connectivity. However, when port 2 is used to perform system service, you
must first enter the
satask chserviceip -techport disable
command to disable the
technician port. You can then use port 2 to provide additional Ethernet connectivity.
b) Connect Ethernet port 1 of each node canister in the system to the IP network that will provide a
connection to the system management interfaces.
Figure 125 on page 120 shows the Ethernet cabling and the ports on the back of a Storwize V5010
system.
Figure 125. Connecting the Ethernet cables to a Storwize V5010 system
Figure 126 on page 121 shows the Ethernet cabling and the ports on the back of a Storwize V5020
system.
120 Storwize V5000 Gen2: Quick Installation Guide
Summary of Contents for Storwize V5000 Gen 2 Series
Page 1: ...IBM Storwize V5000 Gen2 Quick Installation Guide IBM...
Page 5: ...Index 149 v...
Page 6: ...vi...
Page 156: ...130 Storwize V5000 Gen2 Quick Installation Guide...
Page 164: ...138 Storwize V5000 Gen2 Quick Installation Guide...
Page 166: ...140 Storwize V5000 Gen2 Quick Installation Guide...
Page 168: ...142 Storwize V5000 Gen2 Quick Installation Guide...
Page 177: ......
Page 178: ...IBM...