Figure 61. Correct drive installation
In Figure 62 on page 61, the drives are not installed correctly. Slot 1 (A1) does not contain a drive.
In addition, drives are installed in row B even though row A contains empty drive slots.
Figure 62. Incorrect drive installation
4. Touch the static-protective package that contains the drive to any unpainted metal surface on the
enclosure. Wear an anti-static wrist strap to remove the drive from the package.
5. Ensure that the drive handle (
1
in Figure 63 on page 62) of the drive assembly is in the open
(unlocked) position.
6. Align the drive carrier into the appropriate drive slot.
7. Gently push the drive down until it stops and the bottom of the latch is aligned with the top of the
partition. Ensure that the handle is not open more than 45 degrees from the drive carrier. (
2
in
Chapter 2. Installing the system hardware 61